{"title":"Crystal Quest — Well Water Treatment","description":"\u003cp\u003eCrystal Quest well water filtration systems. Engineered to remove iron, sulfur, bacteria, and other contaminants common in private well water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrom the Pure Water Guide:\u003c\/strong\u003e \u003ca href=\"\/blogs\/pure-water-guide\/private-well-water-treatment-guide\"\u003ePrivate Well Water Treatment: A Homeowner's Complete Guide\u003c\/a\u003e · \u003ca href=\"\/blogs\/pure-water-guide\/well-water-vs-city-water\"\u003eWell Water vs. City Water: Key Differences and How to Treat Each\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"commercial-industrial-turbidity-water-filter-system-40-cu-ft","title":"Crystal Quest Commercial 205 GPM Turbidity Water Filter System - 40 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 205 GPM Turbidity Water Filter System - 40 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e52x60x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044313415,"sku":"CQE-CO-02111","price":17696.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-205-gpm-turbidity-water-filter-system-40-cu-ft-8716910.jpg?v=1777186327"},{"product_id":"commercial-industrial-turbidity-water-filter-system-30-cu-ft","title":"Crystal Quest Commercial\/Industrial 200 GPM Turbidity Water Filter System - 30 cu. ft.","description":"\u003cdiv class=\"product-8679017671\"\u003e\n\u003cdiv class=\"section clearfix\"\u003e\n\u003cdiv class=\"description\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-8679027847\"\u003e\n\u003cdiv class=\"section clearfix\"\u003e\n\u003ch1 class=\"description\" itemprop=\"description\"\u003eCrystal Quest Commercial\/Industrial 200 GPM Turbidity Water Filter System - 30 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e40x48x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044313607,"sku":"CQE-CO-02110","price":15568.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-200-gpm-turbidity-water-filter-system-30-cu-ft-2452565.jpg?v=1777186327"},{"product_id":"commercial-industrial-turbidity-water-filter-system-20-cu-ft","title":"Crystal Quest Commercial\/Industrial 185 GPM Turbidity Water Filter System - 20 cu. ft.","description":"\u003cdiv class=\"product-8679017671\"\u003e\n\u003cdiv class=\"section clearfix\"\u003e\n\u003cdiv class=\"description\" itemprop=\"description\"\u003e\n\u003ch1\u003eCrystal Quest Commercial\/Industrial GPM 185 Turbidity Water Filter System - 20 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e36 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e32x32x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044319431,"sku":"CQE-CO-02109","price":13039.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-185-gpm-turbidity-water-filter-system-20-cu-ft-9578955.jpg?v=1777186327"},{"product_id":"commercial-industrial-turbidity-water-filter-system-15-cu-ft","title":"Crystal Quest Commercial\/Industrial 75 GPM Turbidity Water Filter System - 15 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial GPM Turbidity Water Filter System - 15 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e24x24x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044320327,"sku":"CQE-CO-02108","price":8399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-75-gpm-turbidity-water-filter-system-15-cu-ft-2436858.jpg?v=1777186326"},{"product_id":"commercial-industrial-turbidity-water-filter-system-10-cu-ft","title":"Crystal Quest Commercial\/Industrial 60 GPM  Turbidity Water Filter System - 10 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 60 GPM Turbidity Water Filter System - 10 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e24x24x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044325255,"sku":"CQE-CO-02107","price":4715.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-60-gpm-turbidity-water-filter-system-10-cu-ft-3108931.jpg?v=1777186326"},{"product_id":"commercial-industrial-turbidity-water-filter-system-7-cu-ft","title":"Crystal Quest Commercial\/Industrial 35 GPM Turbidity Water Filter System - 7 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 35 GPM Turbidity Water Filter System - 7 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e23x24x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044326087,"sku":"CQE-CO-02106","price":4715.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-35-gpm-turbidity-water-filter-system-7-cu-ft-7032824.jpg?v=1777186326"},{"product_id":"commercial-industrial-turbidity-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial\/Industrial 20 GPM Turbidity Water Filter System - 4 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Turbidity Water Filter System - 4 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e17x18x75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044331783,"sku":"CQE-CO-02105","price":2508.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-20-gpm-turbidity-water-filter-system-4-cu-ft-3317276.jpg?v=1777186326"},{"product_id":"commercial-industrial-anti-scale-water-filter-system-9-25-liters","title":"Crystal Quest Commercial\/Industrial 15 GPM Turbidity Water Filter System - 3 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Turbidity Water Filter System - 3 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\n\u003ch2\u003eTURBIDITY REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e15x16x75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044331847,"sku":"CQE-CO-02104","price":1959.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-15-gpm-turbidity-water-filter-system-3-cu-ft-8489987.jpg?v=1777186327"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-40-cu-ft","title":"Crystal Quest Commercial 205 GPM Iron, Mang, Hydro Sulfide Filter System-40 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 205 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System-40 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e40\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e52x60x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e4,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044331911,"sku":"CQE-CO-02098","price":20042.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-205-gpm-iron-mang-hydro-sulfide-filter-system-40-cu-ft-7541788.jpg?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-30-cu-ft","title":"Crystal Quest Commercial 200 GPM Iron, Mang, Hydro Sulfide Filter System-30 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 200 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System-30 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e46x54x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e3,650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044333767,"sku":"CQE-CO-02097","price":17298.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/files\/crystal-quest-commercial-200-gpm-iron-mang-hydro-sulfide-filter-system-30-cu-ft-8314959.png?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-20-cu-ft","title":"Crystal Quest Commercial 185 GPM Iron, Mang, Hydro Sulfide Filter System - 20 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 185 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 20 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e36 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e40x48x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e2,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044336519,"sku":"CQE-CO-02096","price":14921.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-185-gpm-iron-mang-hydro-sulfide-filter-system-20-cu-ft-8186125.jpg?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-15-cu-ft","title":"Crystal Quest Commercial 75 GPM Iron Manganese \u0026 Hydro Sulfide Filter 15 Cu.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 75 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 15 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e15\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cspan\u003e32x32x95\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e1,735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044336647,"sku":"CQE-CO-02095","price":8175.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-75-gpm-iron-manganese-hydro-sulfide-filter-15-cu-1234964.jpg?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-10-cu-ft","title":"Crystal Quest Commercial 60 GPM Iron Manganese \u0026 Hydro Sulfide  Filter 10 Cu.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 60 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 10 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cspan\u003e24x24x95\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e1,135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044336711,"sku":"CQE-CO-02094","price":5863.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-60-gpm-iron-manganese-hydro-sulfide-filter-10-cu-8835193.jpg?v=1777186327"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-7-cu-ft","title":"Crystal Quest Commercial 35 GPM Iron, Mang, Hydro Sulfide Water Filter System - 7 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 35 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 7 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e23x24x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044337159,"sku":"CQE-CO-02093","price":3661.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-35-gpm-iron-mang-hydro-sulfide-water-filter-system-7-cu-ft-5339675.jpg?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial 20 GPM Iron, Mang, Hydro Sulfide Water Filter System - 4 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 4 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller \/ NXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCQE-CO-02092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpace Required (WxDxH in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17x18x75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044337991,"sku":"CQE-CO-02092","price":2924.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-20-gpm-iron-mang-hydro-sulfide-water-filter-system-4-cu-ft-8333601.jpg?v=1777186326"},{"product_id":"commercial-industrial-iron-manganese-and-hydrogen-sulfide-water-filter-system-3-cu-ft","title":"Crystal Quest Commercial 15 GPM Iron, Mang, and Hydro Sulfide Filter System - 3 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Iron, Manganese, and Hydrogen Sulfide Water Filter System - 3 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eCQE-CO-02091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e2510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e 15x16x75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044338055,"sku":"CQE-CO-02091","price":2025.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-15-gpm-iron-mang-and-hydro-sulfide-filter-system-3-cu-ft-5691264.jpg?v=1777186327"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-40-cu-ft","title":"Crystal Quest Commercial 205 GPM Nitrate Removal Water Filter System - 40 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 205 GPM Nitrate Removal Water Filter System - 40 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e1,200,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e114x50x96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044340679,"sku":"CQE-CO-02090","price":21728.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-205-gpm-nitrate-removal-water-filter-system-40-cu-ft-5270747.jpg?v=1777186326"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-30-cu-ft","title":"Crystal Quest Commercial 200 GPM Nitrate Removal Water Filter System - 30 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 200 GPM Nitrate Removal Water Filter System - 30 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e900,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02089\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e94x44x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344455,"sku":"CQE-CO-02089","price":18368.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/files\/crystal-quest-commercialindustrial-200-gpm-tannin-water-filter-system-30-cu-ft-5752305.png?v=1777186147"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-20-cu-ft","title":"Crystal Quest Commercial 185 GPM Nitrate Removal Water Filter System - 20 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 185 GPM Nitrate Removal Water Filter System - 20 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e450,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e79x41x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344519,"sku":"CQE-CO-02088","price":16992.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-185-gpm-nitrate-removal-water-filter-system-20-cu-ft-1409017.jpg?v=1777186326"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-15-cu-ft","title":"Crystal Quest Commercial 75 GPM Nitrate Removal Water Filter System - 15 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 75 GPM Nitrate Removal Water Filter System - 15 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e450,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e79x41x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344647,"sku":"CQE-CO-02087","price":11040.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-75-gpm-nitrate-removal-water-filter-system-15-cu-ft-5857405.jpg?v=1777186268"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-10-cu-ft","title":"Crystal Quest Commercial 60 GPM Nitrate Removal Water Filter System - 10 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 60 GPM Nitrate Removal Water Filter System - 10 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e300,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e64x32x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344711,"sku":"CQE-CO-02086","price":8050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-60-gpm-nitrate-removal-water-filter-system-10-cu-ft-6184985.jpg?v=1777186268"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-7-cu-ft","title":"Crystal Quest Commercial\/Industrial 35 GPM Nitrate Removal Water Filter System - 7 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 35 GPM Nitrate Removal Water Filter System - 7 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e210,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e56x26x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344775,"sku":"CQE-CO-02085","price":5550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-35-gpm-nitrate-removal-water-filter-system-7-cu-ft-7017885.jpg?v=1777186269"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial\/Industrial 20 GPM Nitrate Removal Water Filter System - 4 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Nitrate Removal Water Filter System - 4 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e120,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02084\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e50x26x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044344839,"sku":"CQE-CO-02084","price":4329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-20-gpm-nitrate-removal-water-filter-system-4-cu-ft-3385689.jpg?v=1777186268"},{"product_id":"commercial-industrial-nitrate-removal-water-filter-system-3-cu-ft","title":"Crystal Quest Commercial\/Industrial 15 GPM Nitrate Removal Water Filter System - 3 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Nitrate Removal Water Filter System - 3 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cb\u003e90,000\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02083\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e48x26x73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044349383,"sku":"CQE-CO-02083","price":3552.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-15-gpm-nitrate-removal-water-filter-system-3-cu-ft-6191498.jpg?v=1777186268"},{"product_id":"commercial-industrial-fluoride-water-filter-system-40-cu-ft","title":"Crystal Quest Commercial\/Industrial 205 GPM Fluoride Water Filter System - 40 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 205 GPM Fluoride Water Filter System - 40 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride. If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e20,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 52 x 60 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044349447,"sku":"CQE-CO-02082","price":25088.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-205-gpm-fluoride-water-filter-system-40-cu-ft-2602618.jpg?v=1777186268"},{"product_id":"commercial-industrial-fluoride-water-filter-system-30-cu-ft","title":"Crystal Quest Commercial\/Industrial 200 GPM Fluoride Water Filter System - 30 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 200 GPM Fluoride Water Filter System - 30 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride. If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e15,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 46 x 54 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044349511,"sku":"CQE-CO-02081","price":20608.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/files\/crystal-quest-commercialindustrial-200-gpm-tannin-water-filter-system-30-cu-ft-5752305.png?v=1777186147"},{"product_id":"commercial-industrial-fluoride-water-filter-system-20-cu-ft","title":"Crystal Quest Commercial\/Industrial 185 GPM Fluoride Water Filter System - 20 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 185 GPM Fluoride Water Filter System - 20 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride. If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e10,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e36 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 40 x 48 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044349575,"sku":"CQE-CO-02080","price":15812.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-185-gpm-fluoride-water-filter-system-20-cu-ft-3523770.jpg?v=1777186268"},{"product_id":"commercial-industrial-fluoride-water-filter-system-15-cu-ft","title":"Crystal Quest Commercial 75 GPM Fluoride Water Filter System - 15 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 75 GPM Fluoride Water Filter System - 15 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride.  If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e7,500,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 32 x 32 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044350215,"sku":"CQE-CO-02079","price":11270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-75-gpm-fluoride-water-filter-system-15-cu-ft-5913126.jpg?v=1777186268"},{"product_id":"commercial-industrial-fluoride-water-filter-system-10-cu-ft","title":"Crystal Quest Commercial\/Industrial 60 GPM Fluoride Water Filter System - 10 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 60 GPM Fluoride Water Filter System - 10 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride.  If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e5,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02078\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 24 x 24 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044353927,"sku":"CQE-CO-02078","price":8395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-60-gpm-fluoride-water-filter-system-10-cu-ft-9068002.jpg?v=1777186267"},{"product_id":"commercial-industrial-fluoride-water-filter-system-7-cu-ft","title":"Crystal Quest Commercial 20 GPM Fluoride Water Filter System - 7 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Fluoride Water Filter System - 7 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride.  If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e3,500,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 23 x 24 x 84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044361095,"sku":"CQE-CO-02077","price":5217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-20-gpm-fluoride-water-filter-system-7-cu-ft-1733470.jpg?v=1777186268"},{"product_id":"commercial-industrial-fluoride-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial 20 GPM Fluoride Water Filter System - 4 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Fluoride Water Filter System - 4 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride.  If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e2,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 17 x 18 x 75 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cspan\u003e\u003cstrong\u003e$4,424\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362183,"sku":"CQE-CO-02076","price":3652.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-20-gpm-fluoride-water-filter-system-4-cu-ft-2991820.jpg?v=1777186267"},{"product_id":"commercial-industrial-fluoride-water-filter-system-3-cu-ft","title":"Crystal Quest Commercial Fluoride 15 GPM Water Filter System - 3 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Fluoride Water Filter System - 3 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available add-ons, please call to have them added to your system.\u003c\/p\u003e\n\u003cp\u003eFluoride (F-) is a common constituent of many minerals. Municipal water treatment plants commonly add fluoride to the water to prevent tooth decay. Generally, they try to maintain a level of 1.5 - 2.5 mg\/l. Concentrations above 5 mg\/l are detrimental to tooth structure. High concentrations are contained in wastewater from the manufacturing of glass and steel, as well as from foundry operations. Organic fluoride is present in vegetables, fruits, and nuts. Inorganic fluorine, under the name of sodium fluoride, is a waste product of aluminum and is used in some rat poisons. The MCL for drinking water established by the U.S. EPA is 4 mg\/l.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003eCrystal Quest Eagle Fluoride Resin contains synthetic aluminum oxide adsorbent media. Specifically designed to have a high affinity for Fluoride, Lead, and Arsenic. It removes metals through a mixture of adsorption and chemical reaction with the media; therefore, the elimination is not reliant on ion exchange. It has a uniform particle size, is physically stable and can be used over a wide pH range.\u003c\/p\u003e\n\u003cp\u003eEagle Activated Charcoal Fluoride Removal Media - Bone char carbon is a unique carbonaceous adsorbent manufactured from the treatment and carbonization of selected grades of animal bone and is used for liquid phase filtration to remove organic and inorganic species such as color bodies and many heavy metals. Bone char is different from activated carbon in that it contains both carbon surface area and hydroxyapatite lattice surface area.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGood adsorption of various heavy metals\u003c\/li\u003e\n\u003cli\u003eProduced from aged bones for better efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains alkalinity in adsorbate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn Eagle Activated Charcoal Fluoride System and Media will accommodate for fluoride removal on municipal water that consists of inorganic fluoride.  If fluoride is organic or from natural water sources such as a well, please speak with a Crystal Quest® Associate for system recommendation as a media blend may be suggested.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity (gallons) at 50 ppm in influent with 10 pp. in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,500,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCQE-CO-02075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMineral Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Flow, GPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Flow, GPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackwash Flow, GPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpace Required, in. (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15x16x75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362311,"sku":"CQE-CO-02075","price":2875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-fluoride-15-gpm-water-filter-system-3-cu-ft-9887710.jpg?v=1777186269"},{"product_id":"commercial-industrial-arsenic-water-filter-system-40-cu-ft","title":"Crystal Quest Commercial\/Industrial 205 GPM Arsenic Water Filter System - 40 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 205 GPM Arsenic Water Filter System - 40 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e20,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 52 x 60 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e4800\u003cbr\u003e4 pallets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362375,"sku":"CQE-CO-02074","price":41888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-205-gpm-arsenic-water-filter-system-40-cu-ft-4270390.jpg?v=1777186268"},{"product_id":"commercial-industrial-arsenic-water-filter-system-30-cu-ft","title":"Crystal Quest Commercial\/Industrial 200 GPM Arsenic Water Filter System - 30 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 200 GPM Arsenic Water Filter System - 30 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e15,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02073\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 46 x 54 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e3650\u003cbr\u003e3 pallets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362439,"sku":"CQE-CO-02073","price":34048.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/files\/crystal-quest-commercialindustrial-200-gpm-tannin-water-filter-system-30-cu-ft-5752305.png?v=1777186147"},{"product_id":"commercial-industrial-arsenic-water-filter-system-20-cu-ft","title":"Crystal Quest Commercial\/Industrial 185 GPM Arsenic Water Filter System - 20 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 185 GPM Arsenic Water Filter System - 20 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e10,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e36 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 40 x 48 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e2400\u003cbr\u003e3 pallets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362503,"sku":"CQE-CO-02072","price":29972.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-185-gpm-arsenic-water-filter-system-20-cu-ft-9862582.jpg?v=1777186267"},{"product_id":"commercial-industrial-arsenic-water-filter-system-15-cu-ft","title":"Crystal Quest Commercial 75 GPM Arsenic Water Filter System - 15 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 75 GPM Arsenic Water Filter System - 15 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e7,500,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02071\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 32 x 32 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e1750\u003cbr\u003e2 pallets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044362567,"sku":"CQE-CO-02071","price":17704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-75-gpm-arsenic-water-filter-system-15-cu-ft-9923614.jpg?v=1777186267"},{"product_id":"commercial-industrial-arsenic-water-filter-system-10-cu-ft","title":"Crystal Quest Commercial\/Industrial 60 GPM Arsenic Water Filter System - 10 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 60 GPM Arsenic Water Filter System - 10 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e5,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 24 x 24 x 95 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e1190\u003cbr\u003e2 pallets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044367111,"sku":"CQE-CO-02070","price":11044.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-60-gpm-arsenic-water-filter-system-10-cu-ft-4659679.jpg?v=1777186267"},{"product_id":"commercial-industrial-arsenic-water-filter-system-7-cu-ft","title":"Crystal Quest 35 GPM Commercial Arsenic Filter System - 7 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 35 GPM Arsenic Water Filter System - 7 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity (Gallons)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e3,500,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 23 x 24 x 84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044367175,"sku":"CQE-CO-02069","price":8107.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-35-gpm-commercial-arsenic-filter-system-7-cu-ft-4055498.jpg?v=1777186267"},{"product_id":"commercial-industrial-arsenic-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial\/Industrial 20 GPM Arsenic Water Filter System - 4 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Arsenic Water Filter System - 4 Cu. Ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e2,000,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 17 x 18 x 75 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044367239,"sku":"CQE-CO-02068","price":5776.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-20-gpm-arsenic-water-filter-system-4-cu-ft-6230534.jpg?v=1777186266"},{"product_id":"commercial-industrial-arsenic-water-filter-system-3-cu-ft","title":"Crystal Quest Commercial\/Industrial Arsenic 15 GPM Water Filter System - 3 Cu. Ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Arsenic Water Filter System - 3 Cu. Ft.\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable backwash cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003cli\u003eUtilizes a strongly basic hybrid anion exchange resin specially formulated to selectively remove arsenic.\u003c\/li\u003e\n\u003cli\u003eExhibits extraordinary throughput capacity in arsenic removal service on potable water supplies. Its performance is virtually unaffected by common anions, such as chlorides, bicarbonates or sulfates. It is effective over the entire pH range of potable water.\u003c\/li\u003e\n\u003cli\u003eMade from NSF\/ANSI-61 validated anion exchange resin\u003c\/li\u003e\n\u003cli\u003eNo arsenic dumping - effluent arsenic levels will not exceed influent levels if the resin is operated past exhaustion point\u003c\/li\u003e\n\u003cli\u003eFiltration capacity: Up to 500,000 gallons per Cu. Ft. Resin (at 50 ppb in influent with 10 ppb in effluent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to backwash based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"8\" cellspacing=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCapacity (Gallons)\u003cbr\u003eat 50 ppb in influent\u003cbr\u003e10 ppb in effluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e1,500,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02067\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e 15 x 16 x 75 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41044367303,"sku":"CQE-CO-02067","price":4662.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-arsenic-15-gpm-water-filter-system-3-cu-ft-7823562.jpg?v=1777186267"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-3-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System - 3 cu. ft.","description":"\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cb\u003e90,000\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e48x26x73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41045887175,"sku":"CQE-CO-02128","price":1770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-3-cu-ft-4590225.jpg?v=1777186149"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-4-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System - 4 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System - 4 cu. ft.\u003c\/h1\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e120,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e24x41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e50x26x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41045956039,"sku":"CQE-CO-02129","price":2320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-4-cu-ft-9190885.jpg?v=1777186148"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-7-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System - 35 GPM 7 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System - 7 cu. ft. 35 GPM\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ctable cellspacing=\"20\" cellpadding=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u003cstrong\u003e210,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eCQE-CO-02130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e3150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e21 x 62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e24x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e56x26x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41045986759,"sku":"CQE-CO-02130","price":3079.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-35-gpm-7-cu-ft-2430866.jpg?v=1777186148"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-10-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System 60 GPM - 10 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System  60 GPM - 10 cu. ft.\u003c\/h1\u003e\n\u003ctable cellspacing=\"20\" cellpadding=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e\n\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u003cstrong\u003e300,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eCQE-CO-02131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eFleck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e2850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e24 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e30x50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" nowrap align=\"left\"\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" nowrap align=\"center\"\u003e64x32x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046030535,"sku":"CQE-CO-02131","price":4474.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-60-gpm-10-cu-ft-2799832.jpg?v=1777186149"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-15-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System - 15 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System - 15 cu. ft.\u003c\/h1\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e450,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e79x41x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046078855,"sku":"CQE-CO-02132","price":8734.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-15-cu-ft-7494977.jpg?v=1777186148"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-20-cu-ft","title":"Crystal Quest Commercial Acid Neutralizing Water System - 20 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System - 20 cu. ft.\u003c\/h1\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cb\u003e600,000\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e36 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e39x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e85x41x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046113159,"sku":"CQE-CO-02133","price":14980.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-acid-neutralizing-water-system-20-cu-ft-1468307.jpg?v=1777186148"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-30-cu-ft","title":"Crystal Quest Commercial Acid Neutralizing Water System - 30 cu. ft.","description":"\u003ch1\u003eCrystal Quest  Commercial\/Industrial Acid Neutralizing Water System - 30 cu. ft.\u003c\/h1\u003e\n\u003ctable cellspacing=\"20\" cellpadding=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"center\"\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u003cstrong\u003e900,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eCQE-CO-02134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e42 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e42x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd nowrap valign=\"middle\" align=\"center\"\u003e94x44x95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046135815,"sku":"CQE-CO-02134","price":16458.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/files\/crystal-quest-commercialindustrial-200-gpm-tannin-water-filter-system-30-cu-ft-5752305.png?v=1777186147"},{"product_id":"commercial-industrial-acid-neutralizing-water-system-40-cu-ft","title":"Crystal Quest Commercial\/Industrial Acid Neutralizing Water System - 40 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial Acid Neutralizing Water System - 40 cu. ft.\u003c\/h1\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cp\u003e\u003cstrong\u003eExchange Capacity \u003c\/strong\u003e\u003cstrong\u003e(grains) @15 #\/Ft3\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e1,200,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Resin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e48 x 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBrine Tank Size, in.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e50x60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e114x50x96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046161671,"sku":"CQE-CO-02135","price":18698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-acid-neutralizing-water-system-40-cu-ft-5108799.jpg?v=1777186148"},{"product_id":"commercial-industrial-tannin-water-filter-system-3-cu-ft","title":"Crystal Quest Commercial\/Industrial 15 GPM Tannin Water Filter System - 3 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 15 GPM Tannin Water Filter System - 3 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e48x26x73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046204103,"sku":"CQE-CO-02136","price":3219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercialindustrial-15-gpm-tannin-water-filter-system-3-cu-ft-3601167.jpg?v=1777186148"},{"product_id":"commercial-industrial-tannin-water-filter-system-4-cu-ft","title":"Crystal Quest Commercial 20 GPM Tannin Water Filter System - 4 cu. ft.","description":"\u003ch1\u003eCrystal Quest Commercial\/Industrial 20 GPM Tannin Water Filter System - 4 cu. ft.\u003c\/h1\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTimer Control Valves\u003c\/li\u003e\n\u003cli\u003eHeavy duty composite fiberglass tanks\u003c\/li\u003e\n\u003cli\u003eHeavy duty Brian Tank\u003c\/li\u003e\n\u003cli\u003eHigh Flow Distributor\u003c\/li\u003e\n\u003cli\u003eAll brass, motor driven control valve with fully adjustable regeneration cycles\u003c\/li\u003e\n\u003cli\u003eSelf-adjusting backwash controller\u003c\/li\u003e\n\u003cli\u003eFlow controller to limit backwash flow\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced water consumption\u003c\/li\u003e\n\u003cli\u003eReduced salt usage\u003c\/li\u003e\n\u003cli\u003eEngineered for commercial \u0026amp; industrial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdd-Ons*\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetered Control Valve\u003c\/li\u003e\n\u003cli\u003eMetered to regenerate based on demand\u003c\/li\u003e\n\u003cli\u003eBackwash or regeneration bypass\u003c\/li\u003e\n\u003cli\u003e3200NT Controller\u003c\/li\u003e\n\u003cli\u003eNo Hard Water Bypass\u003c\/li\u003e\n\u003cli\u003eNXT Upgrade Controller\u003c\/li\u003e\n\u003cli\u003eDuplex parallel, twin alternating, triplex (progressive)\u003c\/li\u003e\n\u003cli\u003eOptional skid mounting for tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*If you are interested in our available Options, please call to have them added to your system.\u003c\/p\u003e\n\u003ctable cellpadding=\"20\" cellspacing=\"20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003e\u003ch2\u003eTANNIN REMOVAL WATER FILTRATION SYSTEM\u003c\/h2\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eCu. Ft. Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003eCQE-CO-02137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e2900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePipe Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eGravel, lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eMineral Tank Size (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e16 x 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eService Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003ePeak Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eBackwash Flow (GPM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eSpace Required\u003cbr\u003e(W x D x H in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e50x26x84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"middle\" nowrap\u003e\u003cstrong\u003eShipping Weight (lbs.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" nowrap\u003e492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:20px; font-size:0.875em; color:#888;\"\u003eNeed higher capacity or a custom configuration? \u003ca href=\"\/pages\/commercial-water-systems-quote\" style=\"color:#003366;\"\u003eView our commercial water solutions →\u003c\/a\u003e\u003c\/p\u003e","brand":"Crystal Quest","offers":[{"title":"Default Title","offer_id":41046236679,"sku":"CQE-CO-02137","price":4329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/products\/crystal-quest-commercial-20-gpm-tannin-water-filter-system-4-cu-ft-5389748.jpg?v=1777186148"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1316\/4373\/collections\/crystal_quest_logo_c0cfd24a-cd09-41df-b083-39a7cd6a3925.png?v=1778899567","url":"https:\/\/purewaterguys.com\/collections\/crystal-quest-well-water-treatment.oembed?page=3","provider":"PureWaterGuys.com","version":"1.0","type":"link"}