June 14, 2026

Hereford, TX Water Quality Report 2026

By PureWaterGuys

EPA compliance testing (2012–2019) detected 19 regulated contaminants in this water system: Gross alpha radioactivity, Fluoride, Uranium + 16 more.

Unlock the full breakdown — detected levels vs. legal limits, plus what removes each one.

Full contaminant breakdown

EPA Six-Year Review compliance monitoring, 2012–2019 — the most recent national compliance dataset EPA has published. See the sections above for more recent violation and PFAS records.

ContaminantAvg. detectedHighest sampleFederal limitAvg. vs. limit
Gross alpha radioactivityEPA health goal: zero 12.1 pCi/L 24 pCi/L 15 pCi/L 81%
Fluoride 2860 ppb 3870 ppb 4000 ppb 72%
UraniumEPA health goal: zero 17.2 ppb 28 ppb 30 ppb 57%
Radium (combined)EPA health goal: zero 1.78 pCi/L 3.2 pCi/L 5 pCi/L 36%
LeadEPA health goal: zero 5.3 ppb 16 ppb 15 ppb (action level) 35%
ArsenicEPA health goal: zero 2.38 ppb 3.9 ppb 10 ppb 24%
Thallium 0.425 ppb 0.425 ppb 2 ppb 21%
Nitrate + nitrite 1860 ppb 4100 ppb 10000 ppb 19%
Nitrate 1660 ppb 4100 ppb 10000 ppb 17%
Cyanide 27.2 ppb 27.2 ppb 200 ppb 14%
Selenium 5.28 ppb 8.1 ppb 50 ppb 11%
Haloacetic acids (HAA5) 4.99 ppb 23.5 ppb 60 ppb 8%
Copper 89.5 ppb 230 ppb 1300 ppb (action level) 7%
Total trihalomethanes (TTHMs) 5.56 ppb 15.5 ppb 80 ppb 7%
Chromium (total) 3.62 ppb 10.4 ppb 100 ppb 4%
Atrazine 0.1 ppb 0.1 ppb 3 ppb 3%
Barium 35 ppb 45 ppb 2000 ppb 2%
p-Dichlorobenzene 0.65 ppb 0.65 ppb 75 ppb 1%
Toluene 0.57 ppb 0.57 ppb 1000 ppb <1%

Also tested, no detections: 1,1,1-Trichloroethane, 1,1,2-Trichloroethane, 1,1-Dichloroethylene, 1,2,4-Trichlorobenzene, 1,2-Dichloroethane, 1,2-Dichloropropane, 2,4,5-TP (Silvex), 2,4-D, Alachlor, Antimony, Asbestos, Benzene, Benzo(a)pyrene, Beryllium, Cadmium, Carbofuran, Carbon tetrachloride, Chlordane, Chlorobenzene, DBCP, DEHA (adipate), DEHP (phthalate), Dalapon, Dichloromethane, Dinoseb, Endrin, Ethylbenzene, Ethylene dibromide (EDB), Heptachlor, Heptachlor epoxide, Hexachlorobenzene, Hexachlorocyclopentadiene, Lindane, Mercury (inorganic), Methoxychlor, Nitrite, Oxamyl, Pentachlorophenol, Picloram, Simazine, Styrene, Tetrachloroethylene (PCE), Toxaphene, Trichloroethylene (TCE), Vinyl chloride, Xylenes (total), cis-1,2-Dichloroethylene, o-Dichlorobenzene, trans-1,2-Dichloroethylene.

Reverse osmosis (drinking water)

The treatment category most often matched to dissolved contaminants like lead, arsenic, nitrate, fluoride, and radiological contaminants detected in this system.

Shop reverse osmosis →

Whole-house carbon filtration

The treatment category most often matched to disinfection byproducts (TTHMs, haloacetic acids), chlorine taste and odor, and organic compounds detected in this system.

Shop whole-house systems →

Source: U.S. EPA Six-Year Review 4 compliance monitoring data (2012–2019), the most recent nationwide compliance dataset EPA has released, reported at the water-system level. A detection is not a violation. “Avg. vs. limit” compares the average of laboratory detections to the federal MCL or action level; individual faucets can differ — household plumbing affects lead and copper, and a state-certified laboratory test of your own tap is the only way to confirm levels in your home. Treatment categories are general matches, not a certification claim for a specific product and contaminant.

Water Utility: Hereford Municipal Water System
Population Served: 16,048 residents
Data Sources: EPA SDWIS + EPA UCMR5
Report Year: 2026

Hereford, Texas drinking water is supplied by Hereford Municipal Water System. All US public water systems must test drinking water and report results to the EPA under the Safe Drinking Water Act. This report summarizes health-based violations and PFAS detections recorded in federal databases to help you make informed decisions about home water filtration.

EPA Health-Based Violation History

The following contaminants exceeded EPA maximum contaminant levels (MCLs) at this utility since 2010:

Contaminant Violation Years Filter Solution
Coliform (Tcr) 2015 Whole House Filters
Gross Alpha, Excl. Radon And U 2016 Water Filters
Lead And Copper Rule Revisions 2024 Whole House Filters

Source: EPA Safe Drinking Water Information System (SDWIS), updated quarterly. Health-based violations only.

Should You Filter Your Hereford Water?

Even utilities with no EPA violations may have contaminants present below legal limits but above health guidelines. The EPA sets maximum contaminant levels based on what is feasible and affordable to treat at scale -- not necessarily what carries zero health risk. Many independent health organizations recommend filtration for households with children, pregnant women, or immunocompromised individuals regardless of utility compliance status.

Protect Your Hereford Home Water

PureWaterGuys.com carries filtration systems designed to protect every tap from lead and copper. We ship to all Texas addresses with free expert guidance on the right system.

Shop Whole House Water Filters →Take the Water Quiz

Frequently Asked Questions

Is Hereford tap water safe to drink?

Hereford Municipal Water System is required to meet EPA federal drinking water standards. However, meeting legal standards is not the same as being contaminant-free. Trace levels of disinfection byproducts, PFAS compounds, and other regulated contaminants are common in US municipal water systems.

Does Hereford water have PFAS?

PFAS monitoring data for this utility may not yet be published in EPA databases. We recommend a reverse osmosis system for maximum protection regardless of local results.

What water filter works best for Hereford?

A whole-house carbon block filter removes chlorine, chloramines, and many VOCs. For PFAS, arsenic, and nitrates, a reverse osmosis under-sink system provides the highest reduction rates. Take our free 2-minute quiz to find the right system for your home and budget.

Data sourced from EPA SDWIS and UCMR5 federal databases. PureWaterGuys.com is not affiliated with any municipal water utility. Contact your utility's annual Consumer Confidence Report (CCR) for complete local data.

← Back to Water Quality Reports