June 14, 2026
San Bernardino, CA Water Quality Report 2026
Unlock the full breakdown — detected levels vs. legal limits, plus what removes each one.
Full contaminant breakdown
EPA Six-Year Review compliance monitoring, 2012–2019 — the most recent national compliance dataset EPA has published. See the sections above for more recent violation and PFAS records.
| Contaminant | Avg. detected | Highest sample | Federal limit | Avg. vs. limit |
|---|---|---|---|---|
| LeadEPA health goal: zero | 40 ppb | 40 ppb | 15 ppb (action level) | 267% — above |
| Nitrate + nitrite | 21100 ppb | 920000 ppb | 10000 ppb | 211% — above |
| UraniumEPA health goal: zero | 14.3 ppb | 28.8 ppb | 30 ppb | 48% |
| ArsenicEPA health goal: zero | 4.58 ppb | 15 ppb | 10 ppb | 46% |
| Nitrate | 4640 ppb | 18000 ppb | 10000 ppb | 46% |
| Tetrachloroethylene (PCE)EPA health goal: zero | 1.84 ppb | 9.2 ppb | 5 ppb | 37% |
| Copper | 224 ppb | 430 ppb | 1300 ppb (action level) | 17% |
| Trichloroethylene (TCE)EPA health goal: zero | 0.757 ppb | 1.7 ppb | 5 ppb | 15% |
| Fluoride | 548 ppb | 1700 ppb | 4000 ppb | 14% |
| 1,2-DichloropropaneEPA health goal: zero | 0.593 ppb | 0.62 ppb | 5 ppb | 12% |
| DichloromethaneEPA health goal: zero | 0.615 ppb | 0.65 ppb | 5 ppb | 12% |
| 1,1-Dichloroethylene | 0.463 ppb | 0.88 ppb | 7 ppb | 7% |
| Haloacetic acids (HAA5) | 4.41 ppb | 10 ppb | 60 ppb | 7% |
| Total trihalomethanes (TTHMs) | 4.55 ppb | 13 ppb | 80 ppb | 6% |
| Carbon tetrachlorideEPA health goal: zero | 0.215 ppb | 0.22 ppb | 5 ppb | 4% |
| BenzeneEPA health goal: zero | 0.15 ppb | 0.15 ppb | 5 ppb | 3% |
| Chromium (total) | 2.1 ppb | 3.9 ppb | 100 ppb | 2% |
| cis-1,2-Dichloroethylene | 0.595 ppb | 1.1 ppb | 70 ppb | 1% |
Also tested, no detections: 1,1,1-Trichloroethane, 1,1,2-Trichloroethane, 1,2,4-Trichlorobenzene, 1,2-Dichloroethane, Antimony, Barium, Beryllium, Cadmium, Chlorobenzene, Cyanide, DBCP, Ethylbenzene, Ethylene dibromide (EDB), Mercury (inorganic), Nitrite, Selenium, Styrene, Thallium, Toluene, Vinyl chloride, Xylenes (total), o-Dichlorobenzene, p-Dichlorobenzene, trans-1,2-Dichloroethylene.
Reverse osmosis (drinking water)
The treatment category most often matched to dissolved contaminants like lead, arsenic, nitrate, fluoride, and radiological contaminants detected in this system.
Shop reverse osmosis →Whole-house carbon filtration
The treatment category most often matched to disinfection byproducts (TTHMs, haloacetic acids), chlorine taste and odor, and organic compounds detected in this system.
Shop whole-house systems →Source: U.S. EPA Six-Year Review 4 compliance monitoring data (2012–2019), the most recent nationwide compliance dataset EPA has released, reported at the water-system level. A detection is not a violation. “Avg. vs. limit” compares the average of laboratory detections to the federal MCL or action level; individual faucets can differ — household plumbing affects lead and copper, and a state-certified laboratory test of your own tap is the only way to confirm levels in your home. Treatment categories are general matches, not a certification claim for a specific product and contaminant.
Water Utility: San Bernardino City
Population Served: 214,665 residents
Data Sources: EPA SDWIS + EPA UCMR5
Report Year: 2026
San Bernardino, California drinking water is supplied by San Bernardino City. All US public water systems must test drinking water and report results to the EPA under the Safe Drinking Water Act. This report summarizes health-based violations and PFAS detections recorded in federal databases to help you make informed decisions about home water filtration.
EPA Violation History
No health-based EPA maximum contaminant level (MCL) violations on record since 2010 for this utility.
PFAS "Forever Chemical" Detections
PFAS compounds were detected in this water system during EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR5) testing program (2023-2025). EPA has set maximum contaminant levels of 4 parts per trillion (ppt) for PFOA and PFOS individually.
| PFAS Compound | Level Detected | Solution |
|---|---|---|
| PFBS | 0.0044 ug/L | PFAS Filters |
| PFHxS | 0.0040 ug/L | PFAS Filters |
| PFHxA | 0.0040 ug/L | PFAS Filters |
| PFPeA | 0.0034 ug/L | PFAS Filters |
Source: EPA UCMR5 occurrence data. Levels in micrograms per liter (ug/L = parts per billion). 1 ug/L = 1,000 ppt.
Should You Filter Your San Bernardino Water?
Even utilities with no EPA violations may have contaminants present below legal limits but above health guidelines. The EPA sets maximum contaminant levels based on what is feasible and affordable to treat at scale -- not necessarily what carries zero health risk. Many independent health organizations recommend filtration for households with children, pregnant women, or immunocompromised individuals regardless of utility compliance status.
Protect Your San Bernardino Home Water
PureWaterGuys.com carries filtration systems certified to reduce PFAS compounds like PFOA and PFOS. We ship to all California addresses with free expert guidance on the right system.
Shop PFAS Water Filters →Take the Water QuizFilters for San Bernardino, CA Water Issues
Based on contaminants detected in this report, these systems are worth considering:
NSF-certified filters proven to remove PFAS, PFOA, PFOS, and 200+ contaminants.
Shop PFAS / Forever Chemicals Filters →
Reverse osmosis systems that reduce nitrates to safe levels.
Shop Nitrates / Nitrites Filters →
Whole-house carbon filters that eliminate chlorine taste, odor, and DBPs.
Shop Chlorine / Disinfection Byproducts Filters →
Frequently Asked Questions
Is San Bernardino tap water safe to drink?
San Bernardino City is required to meet EPA federal drinking water standards. However, meeting legal standards is not the same as being contaminant-free. Trace levels of disinfection byproducts, PFAS compounds, and other regulated contaminants are common in US municipal water systems.
Does San Bernardino water have PFAS?
PFAS compounds were detected in this utility's water during EPA UCMR5 monitoring. A certified PFAS filter -- such as reverse osmosis or activated carbon block -- can significantly reduce these compounds at your tap.
What water filter works best for San Bernardino?
A whole-house carbon block filter removes chlorine, chloramines, and many VOCs. For PFAS, arsenic, and nitrates, a reverse osmosis under-sink system provides the highest reduction rates. Take our free 2-minute quiz to find the right system for your home and budget.
Data sourced from EPA SDWIS and UCMR5 federal databases. PureWaterGuys.com is not affiliated with any municipal water utility. Contact your utility's annual Consumer Confidence Report (CCR) for complete local data.